Home
Power System Products
Engineered Power Systems
Paralleling Switchgear & Controls
Transfer Switch Controls
Microgrid & Switchgear Master Controls
Outdoor Walk-In & Skid-Mounted Switchgear
Unit Substations & Transformers
Medium Voltage MetalClad Switchgear
Medium Voltage Metal Enclosed Switchgear
Grounding Systems
Surge Protection
Low Voltage Switchboards & Switchgear
Load Transfer Switchgear
Generator / Loadbank Quick Connection
Arc Flash Mitigation Switchgear
Industrial Control Panels
Kits & Accessories
Services
Resources
Advanced Power Blog
Technical Papers
Press Releases
Presentations
Helpful External Links
About Us
Careers
Job Postings
Apply Now
Contact Us
SBU-BI 208V-480V UPS, ATS Servicing Bypass/Isolation Panel
Bypass/Isolation for UPS Maintenance with SKRU, & Redundant Bypass/Isolation with Low & Medium Voltage Automatic Transfer Switchgear
Home
»
Power System Products
»
Load Transfer Switchgear
»
SBU-BI 208V-480V Maintenance Bypass/Isolation Switchboard
Site Map
Home
Power System Products
Engineered Power Systems
Paralleling Switchgear & Controls
Transfer Switch Controls
Microgrid & Switchgear Master Controls
Outdoor Walk-In & Skid-Mounted Switchgear
Unit Substations & Transformers
Medium Voltage MetalClad Switchgear
Medium Voltage Metal Enclosed Switchgear
Grounding Systems
Surge Protection
Low Voltage Switchboards & Switchgear
Load Transfer Switchgear
Generator / Loadbank Quick Connection
Arc Flash Mitigation Switchgear
Industrial Control Panels
Kits & Accessories
Services
Resources
Advanced Power Blog
Technical Papers
Press Releases
Presentations
Helpful External Links
About Us
Careers
Job Postings
Apply Now
Contact Us
LV Part Number Configurator & Budgetary Pricing
Url
Product Family (PF)
SBU-Series
PBU-Series
BE1-Series
ArCryptL-Series
WM2-Series
FS2-Series
GM-Series
GenProtectL-Series
PwrMotorL-Series
Control System Modules (CM1)
(MG) – Microgrid
(UI) – APT Utility Intertie
(UP) – APT Utility Paralleling
(GP) – APT "#" Generator Paralleling
(A2) – AdAPTor 2 Generator Paralleling
(N1) – APT N+1 Redundant Generator Control
(PS) – APT Peak Shaving
(ATO) – APT Automatic Standby Open Transfer
(ATC) – APT Automatic Standby Closed Transfer
(SL) – APT Automatic Standby Closed Transfer w/ Soft-loading/Unloading
(NA) – APT Non-Automatic Operator Supervised Return to Normal
(AR) – APT Automatic Return to Normal
(BL) – APT Generator Base Load
(BI) – APT Bypass/Isolation
(MT) – APT Manual Transfer
(IE) – APT Import/Export Control
(LS) – APT Load Shed Control
(EX) – External (Paralleling and/or Transfer)
(XX) – None/Distribution Only
Add More Control System Modules (Optional)
System Voltage (V)
(1) – 120V
(2) – 208V
(4) – 480V
(6) – 600V
Main Bus Ampacity (A)
(X) – 500A
(1) – 1000A
(2) – 2000A
(3) – 3000A
(4) – 4000A
(5) – 5000A
(6) – 6000A
(7) – 7000A
(8) – 8000A
(9) – 9000A
(0) – 10,000A
Interrupting Rating (IR)
(0) – 10kA
(1) – 18kA
(2) – 25kA
(3) – 35kA
(4) – 42kA
(5) – 50kA
(6) – 65kA
(8) – 85kA
(10) – 100kA
(15) – 150kA
(20) – 200kA
Frequency (F)
(6) – 60Hz (Standard)
(5) – 50Hz
Wire (W)
(4) – 3P/4W (Neutral Bus)
(3) – 3P/3W
Enclosure Type (ET)
(01) – NEMA 1
(3R) – NEMA 3R
(RX) – NEMA 3RX (AL/SS)
(PH) – PwrHouse
(PC) – PwrContainer
(S1) – PwrSkid NEMA 1
(S3) – PwrSkid NEMA 3R
(4X) – NEMA 4X
Utility Circuits (U)
(0) – # of Utility Circuit Breakers/Switches
(1) – # of Utility Circuit Breakers/Switches
(2) – # of Utility Circuit Breakers/Switches
(3) – # of Utility Circuit Breakers/Switches
(4) – # of Utility Circuit Breakers/Switches
Generator Circuits (G)
(0) – # of Generator Circuit Breakers/Switches/MLO
(1) – # of Generator Circuit Breakers/Switches/MLO
(2) – # of Generator Circuit Breakers/Switches/MLO
(3) – # of Generator Circuit Breakers/Switches/MLO
(4) – # of Generator Circuit Breakers/Switches/MLO
Tie Circuits (T)
(0) – # of Bus Tie Circuit Breakers/Switches/MLO
(1) – # of Bus Tie Circuit Breakers/Switches/MLO
(2) – # of Bus Tie Circuit Breakers/Switches/MLO
Distribution Circuits (D)
(0) – # of Feeders Circuit Breakers/Switches/MLO
(1) – # of Feeders Circuit Breakers/Switches/MLO
(2) – # of Feeders Circuit Breakers/Switches/MLO
(3) – # of Feeders Circuit Breakers/Switches/MLO
(4) – # of Feeders Circuit Breakers/Switches/MLO
(5) – # of Feeders Circuit Breakers/Switches/MLO
(6) – # of Feeders Circuit Breakers/Switches/MLO
(7) – # of Feeders Circuit Breakers/Switches/MLO
(8) – # of Feeders Circuit Breakers/Switches/MLO
(9) – # of Feeders Circuit Breakers/Switches/MLO
(10) – # of Feeders Circuit Breakers/Switches/MLO
(11) – # of Feeders Circuit Breakers/Switches/MLO
(12) – # of Feeders Circuit Breakers/Switches/MLO
(13) – # of Feeders Circuit Breakers/Switches/MLO
(14) – # of Feeders Circuit Breakers/Switches/MLO
(15) – # of Feeders Circuit Breakers/Switches/MLO
(16) – # of Feeders Circuit Breakers/Switches/MLO
(17) – # of Feeders Circuit Breakers/Switches/MLO
(18) – # of Feeders Circuit Breakers/Switches/MLO
(19) – # of Feeders Circuit Breakers/Switches/MLO
(20) – # of Feeders Circuit Breakers/Switches/MLO
(21) – # of Feeders Circuit Breakers/Switches/MLO
(22) – # of Feeders Circuit Breakers/Switches/MLO
(23) – # of Feeders Circuit Breakers/Switches/MLO
(24) – # of Feeders Circuit Breakers/Switches/MLO
(25) – # of Feeders Circuit Breakers/Switches/MLO
(26) – # of Feeders Circuit Breakers/Switches/MLO
(27) – # of Feeders Circuit Breakers/Switches/MLO
(28) – # of Feeders Circuit Breakers/Switches/MLO
(29) – # of Feeders Circuit Breakers/Switches/MLO
Portable Generator / Load Bank Quick Connection (P)
(4) – 400A Male or Female Cam-loks
(8) – 800A Male or Female Cam-loks
(12) – 1200A Male or Female Cam-loks
(16) – 1600A Male or Female Cam-loks
(20) – 2000A Male or Female Cam-loks
(24) – 2400A Male or Female Cam-loks
(28) – 2800A Male or Female Cam-loks
(32) – 3200A Male or Female Cam-loks
(40) – 4000A Male or Female Cam-loks
(0) – None
Circuit Disconnects (CD)
(IM) – Mixed (any 2+ of the below)
(IF) – ICCB Fixed Mount
(ID) – ICCB Drawout
(MF) – MCCB Fixed Mount
(MD) – MCCB Drawout
(PB) – Mini/Panel CBs
(FS) – Fused Switch
(MC) – Motor Starter + Contactor
(CO) – Contactors Only
(X) – None
Main Bus (MB)
(SC) – Silver Plated Copper
(ES) – Epoxy Coated Silver Plated Copper
(TC) – Tin Plated Copper
(ET) – Epoxy Coated Tin Plated Copper
(X) – None
Potential Transformers (PT)
(D) – Open Delta
(Y) – WYE
(X) – None
Current Transformers (CT)
(1) – Relaying/Power Sensing Only
(2) – Revenue Grade CTs Only
(3) – Relaying & Revenue Grade CTs
(4) – Relaying & Differential Protection
(5) – Relaying, Differential, Revenue Grade CTs
(X) – None
Relay Brand (RB)
(S) – SEL
(M) – GE
(B) – Basler
(W) – Beckwidth
(A) – ABB
(E) – Eaton
(I) – Siemens
(X) – None
AC Control Power (AC)
(1C) – 120VAC Customer Supplied
(05) – 5kVA CPT
(15) – 15kVA CPT
(37) – 37.5kVA CPT
(X) – None
DC Control Power (DC)
(SB) – 24VDC APT Battery System
(24) – 24VDC Customer Supplied
(48) – 48VDC APT Battery System
(4C) – 48VDC Customer Supplied
(25) – 125VDC Customer Supplied
(12) – 125VDC APT Battery System
(50) – 250VDC Customer Supplied
(X) – None
Surge Protection Device (SPD/TVSS)
(1) – Type 1
(2) – Type 2
(3) – Type 3
(X) – None
Grounding System (GS)
(S) – Solid
(L) – Low Resistance (w/NG Resistor)
(H) – High Impedance (w/NG T&R)
(Z) – SunnyGround (Zig-Zag)
(U) – Ungrounded
(X) – Unknown
Master Control Location (MCL)
(1) – Integrated into Line-up Sections
(2) – Integrated 90° Rotated Separate Control Panel
(3) – Isolated Separate Control Panel
(X) – None
Section Cable Entrance (EN)
(T) – Top
(B) – Bottom
(TB) – Top/Bottom
(LR) – Left/Right
(R) – Right Hand Side
(L) – Left Hand Side
(R) – Rear
(M) – Mixed Line-up
Section Cable Exit (EX)
(T) – Top
(B) – Bottom
(TB) – Top/Bottom
(LR) – Left/Right
(R) – Right Hand Side
(L) – Left Hand Side
(R) – Rear
(M) – Mixed Line-up
Other Options 01
(LT) – Circuit Breaker Lift Truck
(BM) – Equipment Mounted to X" Base
(CC) – Harsh Environment Conformal Coating
(GS) – Grounding Studs
(GT) – Ground & Test Device
(LF) – FAC Circuit Breaker Lift Truck
(LO) – Lock Out Relay (86)
(LW) – Premium Winch Circuit Breaker Lift Truck
(MC) – MOC
(PG) – Pistol Grip CB Control Handles
(SL) – Specified Indication Lights (XXmm, XXVDC)
(SS) – SafeStop Circuit Breaker Guard
(TO) – TOC
(UR) – Undervoltage Release
(X) – None
(1G) – 100% Ground
(4G) – 40% Ground
(AC) – Alternate Portable Generator Lug Connections
(AM) – APT Power Metering
(AR) – 120VAC Battery Charger/Convenience Receptacle
(AV) – APTView SCADA System
(BT) – Bus Duct Throat
(CI) – SCADA Connection Interface Terminal Blocks
(CL) – Convenience Light
(CP) – Customer Provided XXXX
(DR) – Load Dump Receptacle/Terminal
(EI) – Ethernet Interface
(EN) – Engraved Nameplates
(ER) – Energy Reduction Maintenance Setting for Trip Units
(FA) – Front Access Only
(FI) – Fiber Interface
(FP) – Fungus Proofing Treatment
(GF) – APT Ground Fault Monitoring
(GL) – Both Generator & Loadbank (Dual sets of Cam-loks)
(HH) – Humidistat
(HR) – Generator Block Heater Receptacle
(IR) – Infrared Windows
(KK) – Kirk Key Interlocking
(LD) – Circuit Breaker Lifting Device
(LK) – Cable Lead Kit
(MB) – Mimic Bus
(ML) – APT Mechanical Lugs
(MW) – Mobility Caster Wheels
(PA) – Remote ATS Position Annunciation
(PL) – Phase Loss Relay
(PM) – Phase Rotation Meter
(PR) – Phase Rotation Monitoring
(RP) – Redundant PLC
(RR) – Remote Racking Device
(SC) – Specified Color:
(SE) – Service Entrance
(SM) – Specified Power Metering
(SP) – Spare Parts
(SR) – Seismic Rated (By Calculations)
(TB) – Generator Remote Start/Stop Terminal Blocks
(TC) – CB Test Cabinet
(TG) – Temporary Generator Only
(TI) – Modbus TCP/IP Interface
(TK) – Trip Unit Test Kit
(TL) – Temporary Loadbank Only
(TP) – Test Plugs
(TR) – 480VAC or 240VAC Twist-lock Receptacle
(TS) – Test Switches
(XL) – Extra Large Enclosure for Conduit Entry/Exit
Other Options 02
(LT) – Circuit Breaker Lift Truck
(BM) – Equipment Mounted to X" Base
(CC) – Harsh Environment Conformal Coating
(GS) – Grounding Studs
(GT) – Ground & Test Device
(LF) – FAC Circuit Breaker Lift Truck
(LO) – Lock Out Relay (86)
(LW) – Premium Winch Circuit Breaker Lift Truck
(MC) – MOC
(PG) – Pistol Grip CB Control Handles
(SL) – Specified Indication Lights (XXmm, XXVDC)
(SS) – SafeStop Circuit Breaker Guard
(TO) – TOC
(UR) – Undervoltage Release
(X) – None
(1G) – 100% Ground
(4G) – 40% Ground
(AC) – Alternate Portable Generator Lug Connections
(AM) – APT Power Metering
(AR) – 120VAC Battery Charger/Convenience Receptacle
(AV) – APTView SCADA System
(BT) – Bus Duct Throat
(CI) – SCADA Connection Interface Terminal Blocks
(CL) – Convenience Light
(CP) – Customer Provided XXXX
(DR) – Load Dump Receptacle/Terminal
(EI) – Ethernet Interface
(EN) – Engraved Nameplates
(ER) – Energy Reduction Maintenance Setting for Trip Units
(FA) – Front Access Only
(FI) – Fiber Interface
(FP) – Fungus Proofing Treatment
(GF) – APT Ground Fault Monitoring
(GL) – Both Generator & Loadbank (Dual sets of Cam-loks)
(HH) – Humidistat
(HR) – Generator Block Heater Receptacle
(IR) – Infrared Windows
(KK) – Kirk Key Interlocking
(LD) – Circuit Breaker Lifting Device
(LK) – Cable Lead Kit
(MB) – Mimic Bus
(ML) – APT Mechanical Lugs
(MW) – Mobility Caster Wheels
(PA) – Remote ATS Position Annunciation
(PL) – Phase Loss Relay
(PM) – Phase Rotation Meter
(PR) – Phase Rotation Monitoring
(RP) – Redundant PLC
(RR) – Remote Racking Device
(SC) – Specified Color:
(SE) – Service Entrance
(SM) – Specified Power Metering
(SP) – Spare Parts
(SR) – Seismic Rated (By Calculations)
(TB) – Generator Remote Start/Stop Terminal Blocks
(TC) – CB Test Cabinet
(TG) – Temporary Generator Only
(TI) – Modbus TCP/IP Interface
(TK) – Trip Unit Test Kit
(TL) – Temporary Loadbank Only
(TP) – Test Plugs
(TR) – 480VAC or 240VAC Twist-lock Receptacle
(TS) – Test Switches
(XL) – Extra Large Enclosure for Conduit Entry/Exit
Other Options 03
(LT) – Circuit Breaker Lift Truck
(BM) – Equipment Mounted to X" Base
(CC) – Harsh Environment Conformal Coating
(GS) – Grounding Studs
(GT) – Ground & Test Device
(LF) – FAC Circuit Breaker Lift Truck
(LO) – Lock Out Relay (86)
(LW) – Premium Winch Circuit Breaker Lift Truck
(MC) – MOC
(PG) – Pistol Grip CB Control Handles
(SL) – Specified Indication Lights (XXmm, XXVDC)
(SS) – SafeStop Circuit Breaker Guard
(TO) – TOC
(UR) – Undervoltage Release
(X) – None
(1G) – 100% Ground
(4G) – 40% Ground
(AC) – Alternate Portable Generator Lug Connections
(AM) – APT Power Metering
(AR) – 120VAC Battery Charger/Convenience Receptacle
(AV) – APTView SCADA System
(BT) – Bus Duct Throat
(CI) – SCADA Connection Interface Terminal Blocks
(CL) – Convenience Light
(CP) – Customer Provided XXXX
(DR) – Load Dump Receptacle/Terminal
(EI) – Ethernet Interface
(EN) – Engraved Nameplates
(ER) – Energy Reduction Maintenance Setting for Trip Units
(FA) – Front Access Only
(FI) – Fiber Interface
(FP) – Fungus Proofing Treatment
(GF) – APT Ground Fault Monitoring
(GL) – Both Generator & Loadbank (Dual sets of Cam-loks)
(HH) – Humidistat
(HR) – Generator Block Heater Receptacle
(IR) – Infrared Windows
(KK) – Kirk Key Interlocking
(LD) – Circuit Breaker Lifting Device
(LK) – Cable Lead Kit
(MB) – Mimic Bus
(ML) – APT Mechanical Lugs
(MW) – Mobility Caster Wheels
(PA) – Remote ATS Position Annunciation
(PL) – Phase Loss Relay
(PM) – Phase Rotation Meter
(PR) – Phase Rotation Monitoring
(RP) – Redundant PLC
(RR) – Remote Racking Device
(SC) – Specified Color:
(SE) – Service Entrance
(SM) – Specified Power Metering
(SP) – Spare Parts
(SR) – Seismic Rated (By Calculations)
(TB) – Generator Remote Start/Stop Terminal Blocks
(TC) – CB Test Cabinet
(TG) – Temporary Generator Only
(TI) – Modbus TCP/IP Interface
(TK) – Trip Unit Test Kit
(TL) – Temporary Loadbank Only
(TP) – Test Plugs
(TR) – 480VAC or 240VAC Twist-lock Receptacle
(TS) – Test Switches
(XL) – Extra Large Enclosure for Conduit Entry/Exit
Other Options 04
(LT) – Circuit Breaker Lift Truck
(BM) – Equipment Mounted to X" Base
(CC) – Harsh Environment Conformal Coating
(GS) – Grounding Studs
(GT) – Ground & Test Device
(LF) – FAC Circuit Breaker Lift Truck
(LO) – Lock Out Relay (86)
(LW) – Premium Winch Circuit Breaker Lift Truck
(MC) – MOC
(PG) – Pistol Grip CB Control Handles
(SL) – Specified Indication Lights (XXmm, XXVDC)
(SS) – SafeStop Circuit Breaker Guard
(TO) – TOC
(UR) – Undervoltage Release
(X) – None
(1G) – 100% Ground
(4G) – 40% Ground
(AC) – Alternate Portable Generator Lug Connections
(AM) – APT Power Metering
(AR) – 120VAC Battery Charger/Convenience Receptacle
(AV) – APTView SCADA System
(BT) – Bus Duct Throat
(CI) – SCADA Connection Interface Terminal Blocks
(CL) – Convenience Light
(CP) – Customer Provided XXXX
(DR) – Load Dump Receptacle/Terminal
(EI) – Ethernet Interface
(EN) – Engraved Nameplates
(ER) – Energy Reduction Maintenance Setting for Trip Units
(FA) – Front Access Only
(FI) – Fiber Interface
(FP) – Fungus Proofing Treatment
(GF) – APT Ground Fault Monitoring
(GL) – Both Generator & Loadbank (Dual sets of Cam-loks)
(HH) – Humidistat
(HR) – Generator Block Heater Receptacle
(IR) – Infrared Windows
(KK) – Kirk Key Interlocking
(LD) – Circuit Breaker Lifting Device
(LK) – Cable Lead Kit
(MB) – Mimic Bus
(ML) – APT Mechanical Lugs
(MW) – Mobility Caster Wheels
(PA) – Remote ATS Position Annunciation
(PL) – Phase Loss Relay
(PM) – Phase Rotation Meter
(PR) – Phase Rotation Monitoring
(RP) – Redundant PLC
(RR) – Remote Racking Device
(SC) – Specified Color:
(SE) – Service Entrance
(SM) – Specified Power Metering
(SP) – Spare Parts
(SR) – Seismic Rated (By Calculations)
(TB) – Generator Remote Start/Stop Terminal Blocks
(TC) – CB Test Cabinet
(TG) – Temporary Generator Only
(TI) – Modbus TCP/IP Interface
(TK) – Trip Unit Test Kit
(TL) – Temporary Loadbank Only
(TP) – Test Plugs
(TR) – 480VAC or 240VAC Twist-lock Receptacle
(TS) – Test Switches
(XL) – Extra Large Enclosure for Conduit Entry/Exit
Other Options 05
(LT) – Circuit Breaker Lift Truck
(BM) – Equipment Mounted to X" Base
(CC) – Harsh Environment Conformal Coating
(GS) – Grounding Studs
(GT) – Ground & Test Device
(LF) – FAC Circuit Breaker Lift Truck
(LO) – Lock Out Relay (86)
(LW) – Premium Winch Circuit Breaker Lift Truck
(MC) – MOC
(PG) – Pistol Grip CB Control Handles
(SL) – Specified Indication Lights (XXmm, XXVDC)
(SS) – SafeStop Circuit Breaker Guard
(TO) – TOC
(UR) – Undervoltage Release
(X) – None
(1G) – 100% Ground
(4G) – 40% Ground
(AC) – Alternate Portable Generator Lug Connections
(AM) – APT Power Metering
(AR) – 120VAC Battery Charger/Convenience Receptacle
(AV) – APTView SCADA System
(BT) – Bus Duct Throat
(CI) – SCADA Connection Interface Terminal Blocks
(CL) – Convenience Light
(CP) – Customer Provided XXXX
(DR) – Load Dump Receptacle/Terminal
(EI) – Ethernet Interface
(EN) – Engraved Nameplates
(ER) – Energy Reduction Maintenance Setting for Trip Units
(FA) – Front Access Only
(FI) – Fiber Interface
(FP) – Fungus Proofing Treatment
(GF) – APT Ground Fault Monitoring
(GL) – Both Generator & Loadbank (Dual sets of Cam-loks)
(HH) – Humidistat
(HR) – Generator Block Heater Receptacle
(IR) – Infrared Windows
(KK) – Kirk Key Interlocking
(LD) – Circuit Breaker Lifting Device
(LK) – Cable Lead Kit
(MB) – Mimic Bus
(ML) – APT Mechanical Lugs
(MW) – Mobility Caster Wheels
(PA) – Remote ATS Position Annunciation
(PL) – Phase Loss Relay
(PM) – Phase Rotation Meter
(PR) – Phase Rotation Monitoring
(RP) – Redundant PLC
(RR) – Remote Racking Device
(SC) – Specified Color:
(SE) – Service Entrance
(SM) – Specified Power Metering
(SP) – Spare Parts
(SR) – Seismic Rated (By Calculations)
(TB) – Generator Remote Start/Stop Terminal Blocks
(TC) – CB Test Cabinet
(TG) – Temporary Generator Only
(TI) – Modbus TCP/IP Interface
(TK) – Trip Unit Test Kit
(TL) – Temporary Loadbank Only
(TP) – Test Plugs
(TR) – 480VAC or 240VAC Twist-lock Receptacle
(TS) – Test Switches
(XL) – Extra Large Enclosure for Conduit Entry/Exit
Add More Options (Optional)
Budgetary Price
Total:
Product Information
This product works best in Generator & UPS applications.
Product Literature
APT SBU-ATO-BI 208V-480V Automatic Transfer Switchboard With Bypass Isolation Brochure
APT Control System Modules
Engineering Bid Specifications
APT SBU-Series 208V-480V UL Listed Switchboards Control Switchgear Specification
Installation Drawings & Diagrams
APT Standard Switchboard/Switchgear Control Enclosure 26" W x 22.5" D x 80" H
APT Standard Switchboard/Switchgear Control Enclosure 26" W x 30.5" D x 80" H
APT Standard Switchboard/Switchgear Control Enclosure 26" W x 38.5" D x 80" H
APT Standard Switchboard/Switchgear Control Enclosure 36" W x 22.5" D x 80" H
APT Standard Switchboard/Switchgear Control Enclosure 36" W x 30.5" D x 80" H
APT Standard Switchboard/Switchgear Control Enclosure 36" W x 36" D x 80" H
Applicable Standards
Previous
Next
Related Products
WM2-MT 208V-480V SE GQC Manual Transfer Tap Box
FS2-T 208V-480V SE GQC Transfer Switchboard
FAC-AT 2.4kV-38kV Front Access Compact Automatic Transfer Switchgear (ATS)
SBU-ATO-BI Bypass/Isolation Automatic Transfer Switchboard
AZ-Series 208V-480V Automatic Transfer Switch
SBU-AT Circuit Breaker Based Automatic Transfer Switchboard
MF2-MT Generator Quick Connection Manual Transfer Switchgear
MES-MT Manual Transfer Switchgear (MTS)
MS6-AT 2.4kV-15kV Compact Medium Voltage Automatic Transfer Switch (ATS)
15A-AT 2.4kV-15kV MetalClad Automatic Transfer Switchgear (ATS)